EE046冷凝报警器有助于防止冷凝梁和其他关键冷点上的冷凝,并适用于安装在平面和最大直径为50毫米(2 ")的管道上.
当物体表面周围的空气相对湿度(RH)达到100%RH时,表面会发生冷凝. 依靠与表面非常好的热耦合,EE046可精确测量表面温度下的空气相对湿度.
在冷凝实际发生之前,继电器输出会在接近冷凝条件时发出预警. 该产品还会提示电源故障或电缆损坏. 状态LED灯指示正常运行,冷凝危险或电源故障.E+E专利涂层保护湿度敏感元件免受灰尘和污染物影响.
Key Features
可靠的监测冷凝危险
快速响应时间
E+E专利镀膜保护防止灰尘污染
紧凑型设计方便安装
LED状态指示
典型应用
冷冻梁
开关柜
环境控制
技术资料
10...100% RH
工作范围
90 ±3% RH
开关节点
t90 < 3 min.
表面温度变化响应时间
t90 < 25 sec.
相对湿度变化响应时间
24 V AC/DC, 1 A
最大开关负载
24 V AC/DC
供电
EE046 condensation monitor is used for detecting the danger of condensation on pipes, ducts and other surfaces before condensation actually occurs.
The device measures the relative humidity at the surface to be monitored and provides an early warning signal (relay) when the humidity reaches 90% RH.
The signal can be used for initiating control steps such as increasing the water temperature in a chilled ceiling, reducing the cooling capacity or switching on the heating.A special coating protects electronics and sensor against contamination.
Key Features
Early detection of condensation danger
High accuracy and long term stability
Compact design
Fast response time
Sensor protection
Easy mounting and wiring
LED status indication
Typical Applications
Chilled ceilings
HVAC, buliding automation
Rectifier cabinets for wind power generatiors